Load cell : CWW

 

  • These load cells are extremely Slim and lightweight.
  • Easy installation with hole in center.
  • Designed for use in civil engineering measurement, these loads on tunnel supports and soil pressure on protective Walls to aid control in construction projects.
  • Protection Class IP67

 

 

Specifications

SpecificationsAccuracy
Rated capacity(R.C) 50kgf, 100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf,10tf, 20tf, 30tf, 50tf, 100tf, 150tf, 200tf
(490.3N, 980.7N, 1.961kN, 4.903kN, 9.807kN, 19.61kN, 29.42kN, 49.03kN, 98.07kN, 196.1kN, 490.3kN, 980.7kN, 1.961MN)
Rated output(R.O) 1.5mV/V±0.4%
Nonlinearity 1% of R.O.
Hysteresis 0.5% of R.O.
Repeatability 0.5% of R.O.
Zero balance 0.5% of R.O.
Terminal resistance input 700 ±10Ω
Terminal resistance output 700 ±5Ω
Insulation resistance 2000Ω
Temperature range, compensated -10~60℃
Temperature range, Safe -20~80℃
Temperature effect, on zero balance 0.1% R.O./10℃
Temperature effect, on rated output 0.05% R.O./10℃
Excitation recommended

 

10V

 

150% R.C

 

Φ7mm 4core, 3m

Safe overload
Cable length

Dimensions

CapacityΦAΦBΦCDEWeight(kg)
50kgf 10 55 22 15 2 2
100kgf
200kgf
500kgf
1tf 12 68 28 20 1.5 2.5
2tf
3tf
5tf
10tf 50 148 80 37 5 3
20tf 70 155 99 43 5 6
30tf
50tf
100tf 110 198 129 43 5 8
150tf 165 278 200 50 8 20
200tf 170 308 212 65 10 27

 

 

Cr : http://www.dacell.com