Load cell : CP,CP57

 

  • A compact and low cost, shear type compression load cell.
  • It is a comparatively low cost shear type transducers with a high accurary of 0.02% R.O.
  • Platform and Tank scale weighing.

 

 

SpecificationsAccuracy
Ratecapacity (R.C) 50kgf, 100gkf, 150kgf, 300kgf, 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 12tf
490.3N, 980.7N, 1.471KN, 2.942KN, 4.903KN, 9.807KN, 19.61KN,
29.42KN, 49.03KN, 58.84KN, 98.07KN, 117.7KN
output (R.O) 2mv/v±0.1%
Nonlinearity 0.03% of R.O.
Hysteresis 0.02% of R.O.
Creep(20min) 0.02% of R.O.
Repeatability 0.03% of R.O.
Zero balance ±5% of R.O.
Temperature
effect
on rated output 0.02% of LOAD/10℃
on zero balance 0.05% of R.O./10℃
Temperature
range
compensated -10~50℃
safe -10~50℃
Terminal
resistance
input 350 ±30Ω
output 350 ±3Ω
Insulation resistance bridge 2000MΩ
Excitation recommended 10V
Safe overload 150%
Cable length Φ7±0.3mm 4core, 3m

 

ModelCapacityABCDEFGHIΦJΦK
CP5kgf - 300kgf 135 36 26 17 75 25 18 32 58 11.5 11.5
500kgf - 2tf 135 38 30 17 75 25 18 34 58 13.5 13.5
3 - 5tf 170 48 38 20 85 50 15 39 79 18.5 18.5
6tf 203 48 50 23 95 62 23 39 110 24.5 24.5
10 - 12tf 263 60 60 30 118 90 25 52 143 26 26
CP57500kgf - 2tf 131 38 30 12.7 76.2 25.4 16.7 34 57 13.5 13.5
3 - 5tf 171 44.5 38 19 95 38 19 38 76.2 20.5 20
10tf 222.3 57.2 50.8 25.4 147.1 50.8 25.4 50.8 101 26.2 26.2

 

 

Cr : http://www.dacell.com