8CH Alarm Output Digital Indicator : SC1800 / SC2800
SC1800 and SC2800 Indicator have a Micro Processor. The model is able to convert diversified Input to 8step NPN Open Collector Output. Especially devised for heavy industry. Easy setting by click the front button, it is possible to set Step, full scale values, the decimal point and Calibration. When power outages it retains its data.
Feature
Input Signal: 1~3mV/V(SC1800), V or mA(SC2800)
STEP or SETTING LED & DISPLAY LED
Max Readout : 0.000~9999
Auto Zero Point Setting
Flexible NPN Open Collector TR Output
TR Output method is changeable
Function: Data Hold, Peak Hold, Reset
Frequency Filter : 1, 10, 100Hz(DIP S/W)
48mm×96mm Aluminum Case
SC1800 | SC2800 | |
Sensor Sensor Excitation Sensor Supply Current Sensor Output Sensor Impedance |
5VDC Max 120mA 1~3mV/V(DIP S/W Adjust) 120 or 350Ω |
24VDC(3~28VDC Adjust) MAX 100mA(24VDC) 0~5,1~5V,0~10VDC 4~20mA(DIP S/W Adjust) - |
Analog Input Impedance Frequency Filter Thermal Effect |
More than 5MΩ | mA Input 250Ω V Input More than 5kΩ |
1, 10, 100Hz, 4kHz 0.02%FS/℃ |
||
Digital A/D Sampling Time A/D Resolution Max Readout Height of Digits STEP Display LED Linearity Decimal point Setting Display Type |
15 or 30 or 120 times/sec ±4½ Digit 0.000~9999 14mm(H)×8mm(W) 7 SEGMENT LED(Green) ±0.02%FS Be Able to set number of 3 decimal by front switch 7 SEGMENT LED |
|
General 8 STEP TR Output Electrical Connection Power Storage Temperature Operating Temperature Mounting Type Size Weight |
8 STEP NPN OPEN COLLECTOR TR Output SCREW TERMINAL Connection AC110(50~60Hz), AC220V(50~60Hz) -40~80℃ 0~50℃ Panel 96(W)×48(H)×110(D) 1/8DIN 570g |
|
Option | Sensor Output : Less than 0.75mV/V More than 3.5mV/V |
Sensor Power : ±15VDC |
Cr. : http://www.sensys.co.kr