OEM Flow Turbine :: Vision® 1000
Flow range: 0.1 - 2.5 l/min
Grilamid Body : 1/4" BSP
Features
• Low cost
• Flow range: 0.1 - 2.5 l/min
• Simple construction
• Length 45 mm, weight 10 gr
• High repeatability
• Pulse output
• Temperature range -20 to +100°C
• Operating pressure 25 bar
Features
- Low cost
- Flow range: 0,1 - 2,5 l/min
- Simple construction
- Length 45 mm, weight 10 gr
- High repeatability
- Digital output
- Temperature range -20 to +100°C
- Operating pressure 25 bar
Model number | Flow range l/min | Pulses/l | Frequency/Hz | DN | Air split/mm |
167527 | 0.1 - 2.5 | 22'000 | 33 - 833 | 5 | 0.1 |
Version suitable for Ethanol / Methanol (price on request)
Model number | Flow range l/min | Pulses/l | Frequency/Hz | DN | Air split/mm |
46540-163-2F66 | 0.1 - 2.5 | 22'000 | 33 - 833 | 5 | 0.1 |
Specifications
Flow rates | 0.1 - 2.5 l/min (start: 0.07 l/min) |
flow medium | Liquids without particles, we recommend filtration with approx. 20 to 40 micros |
Pressure rating | 25 bar (100 bar bursting pressure) |
End connection | G 1/4" or NPT 1/4" (maximum torque approx. 6Nm) |
Temperature range | -20 - +100°C |
accuracy | > 0.25 l : +/- 3% of reading < 0.25 l : +/- 3% of end value |
Repeatability | better than 0.5 % |
Viscosity | up to approx. 15cSt |
Pressure drop | refer to table |
El. connection | Connector bases with 3 flat connectors 2,8 x 0,5 fitted for electrical connector EN 60529 |
Power supply | 5 - 24 VDC |
Power consumption | approx. 8mA |
Output signal | Frequency open collector (NPN sinking) |
Output current | max. 20mA |
Materials | Body: Grilamid TR55 (PA12) version suitable for Ethanol / Methanol: Grivory HT1V-5 FWA Turbine: PA12 Ferrit Bearings: PTFE / Graphite |
Certificates | All parts that are touching the medium possess the certificate for cold- and warm water |
Dimensions of sealing | Inside Ø 7 mm, outside Ø 13 mm, thickness 2 mm, hardness approx. 70Sh A |
For orders over 10'000 pieces we can respond to customers wishes regarding the connection of the medium and the electrical connections.
Pressure drop
Connector bases with 3 flat connectors fitted for electrical connector EN 60529
Operating and Installation Instructions
- Check compatibility of media with sensor material Grilamid TR55 (PA 12)
- Filtration is mandatory if solid particles or fibres are present
- Install sensor into properly cleaned pipeline
- Check electrical connection according to the electrical wiring plan
- Do not exceed the specification limits
- The VISION 1000 ® is a volumetric measuring device, i.e. air/gas in liquid will be included in measured volume
- Correctly installed the sensor works entirely maintenance free
- The VISION 1000 ® is not for general public use and is to be installed and applied by trained personnel only
We recommend to test the sensor for the intended purpose and to ascertain - independent of specifications - feasibility of application.
Vision® 1000 Downloads