Panel Meter : MP5S/MP5Y/MP5W/MP5M Series

Pulse(Rate) Meter

Pulse(Rate) Meter

High performance digital pulse meter MP5 Series supports 13 kinds of operation modes to measure various industrial numerical data including Frequency, Absolute ratio, Passing time and Error ratio. (MP5M Series have 11 operation modes only.) Having diverse functions with various output types, the series could be widely used in any industrial fields. 50kHz of high speed response time is another feature to improve user’s convenience.

*13 kinds of various operation modes :
 Revolution, Speed, Frequency, Absolute ratio, Passing time, Error ratio, Period, Density, Passing speed, Error, Time width, Length measurement, Interval, Integration, Multiplication(MP5M Series have 11 operation modes)
*Various output function :
 Relay output, NPN/PNP open collector output, Low speed serial output, BCD output, PV transmission, RS485 communication output
*Various functions :
 Prescale function, Data monitoring function, Hysteresis width setting function, Max./Min. value monitoring function, Delay function, Auto zero time setting function, Lock setting function, Delay of display period function
*Max. display range : -19999 ~ 99999(MP5M:0~99999)
*Various display units : rpm, rps, Hz, kHz, sec, min, m, mm, mm/s, m/s, m/min, m/h, ℓ/s, ℓ/min, ℓ/h, %, counts, etc.
*Selectable voltage input(PNP) or No voltage input(NPN)
*50kHz High speed response function

 

Specification Table

Series MP5S-4N  MP5Y-2□ MP5Y-4□ MP5W-2□ MP5W-4□
Display method 7 Segment LED display(Zero blanking type)
Character size W4 x H8mm W6.8 x H13.8mm
Max. indication -19999 to 99999
Power supply 100-240VAC 50/60Hz 24VDC 100-240VAC 50/60Hz 24VDC 100-240VAC 50/60Hz
Allowable operation voltage Allowable operation voltage : 90 to 110%
Power consumption Max. 7.5VA Max. 6W Max. 7VA Max. 7W |Max. 6VA
Power for external sensor 12VDC ±10%, 80mA
Input frequency • Solid-state Input: Max. 50kHz(Pulse width : Each over 10㎲) 
• Contact input: Max. 45Hz(Pulse width : Over 11ms)
Input level [Voltage input] High : 4.5-24VDC, Low : 0-1.0VDC, Input Impedance : 4.5kΩ 
[No-voltage Input] Impedance at short-circuit: Max. 300Ω, Residual voltage : Max. 1V, Impedance at open-circuit: Min. 100kΩ
Measuring range • Mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz    • Mode F3 : 0.02s to 3,200s 
• Mode F4, F5, F6 : 0.01s to 3,200s    • Mode F11, F12, F13 : 0 to 4 x 10 Count
Measuring accuracy (23 ±5°C) • Mode F1, F2, F7, F8, F9, F10 : F.S. ±0.05% rdg ±1digit   • Mode F3, F4, F5, F6 : F.S. ±0.01% rdg ±1 digit
Display period 0.05 / 0.5 /1 / 2 / 4 / 8sec.(lt Is same with period of output update.)
Operation mode Number of revolution/Speed/Frequency(F1), Passing speed(F2), Cycle(F3), Passing time(F4), Time width(F5), Time defference(F6), Absolute ratio(F7), Error ratio(F8), Density(F9), Error(F10), Length measurement(F11), lnterval(F12), Multiplication(F13) 
※Refer to the M-20 to 23 for the operation mode.
Prescale function Direct Input method(0.0001x10-8 to 9.9999x109)
Hysteresis※1 0 to 9999
Other functions • Lock setting function 
• Auto-Zero time setting function 
• Time unit selection function 
• Peak value monitoring function 
• Memory protection function (Mode F13 applied only)
• Lock setting function 
• Monitoring delay functionUAuto-zero time setting function 
• Current output range selectlon(Current output type only) 
• Comparative output function(HH, H, GO, L, LL) 
• Time unit selection function 
• Deviation memory function(F output mode applied only) 
• Peak value monitoring function 
• Remote/Local switching function(Communicatlon output type only) 
• Data bank switching function※2 
• Memory protection function(Mode F13 applied only)
Main output Triple relay - - 250VAC 3A resistive load 3a
Quintuple relay
NPN Open collector (Quintuple) 12-24VDC 30mA Max. 12-24VDC 20mA Max.
PNP Open collector (Quintuple)
Sub output BCD Dynamic - NPN Open collector 12-24VDC 30mA Max. NPN Open collector 12-24VDC 20mA Max.
Low speed serial output - -
PV transmission - DC4-20mA Load 600Ω Max. (Response time : Max. 800ms) DC4-20mA Load 600Ω Max.
RS485 communication - 32 channels, Mutual direction communication function
Memory protection Non-volatile memory(lnput: Min. 100,000 times)
Insulation resistance Min. 100MΩ(at 500VDC megger) Between charge part and non-charge part
Dielectric stength 2000VAC 60Hz 1minute(Between terminals of AC power and case, 
Between terminals of AC power and measuring input terminals)
Impulse noise stength ±2000VAC the square wave noise(pulse width : 1㎲)by the noise simulator, repeat frequency 60Hz
Vibration Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 mln.) in each of X, Y, Z directions for 10 minutes
Shock Mechanical 300m/s2(30G) in each of X, Y, Z directions for 3 times
Malfunction 100m/s2(10G) in each of X, Y, Z directions for 3 times
Relay life cycle Malfunction - Min. 10,000,000 operations
Mechanical - Min. 100,000 operations(250VAC 3Aload current)
Environ -ment Ambient temperature -10 to 50°C, storage : -20 to 60°C
Ambient humidity 35 to 85%RH, storage : 35 to 85%RH
Unit weight Approx. 130g Approx. 135g Approx. 230g
Approval CE, UL - CE, UL - CE, UL

※1: The hysteresis setting range is changed by the setting position of decimal point. (Refer to M-25 for hysteresis function.)
※2: Data bank switching function Is In MP5W series only.

 

Cr. : http://www.autonics.com/