Panel Meter : Ampere meter

M4Y/M4W/M5W/M4M Series

M4Y/M4W/M5W/M4M Series

Panel meter for measuring DC, AC ampere M4Y/M4W/M4M/M5W series consists of various kinds of model types including indicator and single/dual preset type to allow users more diverse selection. Also, RMS/AVG value selection function contributes to better users’ convenience. Diverse functions including auto zero function, Hold function (except M5W) and 19999(M5W), 1999(others) of maximum display range are another feature of this series.

*Max. display: 19999(M5W), 1999(Others)
*Auto zero function or Hold function(Except for M5W)
*RMS/AVG value selection function(AC Voltage)
*7 Segment LED Display
*Case size by DIN specification
*Indication type only, Single preset output type, Dual preset output type

 

Specification Table

Classification Indicator Single preset output type Dual preset output type
Measurement DC, AC voltage M4Y-DV-☐
M4Y-AV-☐
M5W-DV-☐
M5W-AV-☐
M4W-DV-☐
M4W-AV-☐-☐
M4M-DV-☐
M4M-AV-☐-☐
M4W1P-DV-☐
M4W1P-AV-☐
M4M1P-DV-☐
M4M1P-AV-☐
M4W2P-DV-☐
M4W2P-AV-☐
M4M2P-DV-☐
M4M2P-AV-☐
DC, AC ampere M4Y-DA-☐
M4Y-AA-☐
M5W-DA-☐
M5W-AA-☐
M4W-DA-☐
M4W-AA-☐-☐
M4M-DA-☐
M4M-AA-☐-☐
M4W1P-DA-☐
M4W1P-AA-☐-☐
M4M1P-DA-☐
M4M1P-AA-☐-☐
M4W2P-DA-☐
M4W2P-AA-☐-☐
M4M2P-DA-☐
M4M2P-AA-☐-☐
AC power (0-10VDC) M4Y-W-☐
M5W-W-☐
M4W-W-☐
M4M-W-☐
M4W1P-W-☐
M4M1P-W-☐
M4W2P-W
M4M2P-W
rpm, speed (0-10VDC) (0-10VAC) M4Y-T☐-☐
M4Y-S☐-☐
M5W-T-☐
M5W-S-☐
M4W-T☐-☐
M4W-S☐- ☐
M4M-T- ☐
M4M-S- ☐
M4W1P-T☐-☐
M4W1P-S☐-☐
M4M1P-T-☐
M4M1P-S-☐
M4W2P-T☐-☐
M4W2P-S☐-☐
M4M2P-T-☐
M4M2P-S☐
Power factor (DC4-20mA) - M4W-P
(Refer to L-59)
- -
Max. allowable input 150% for each input specification(At 400VAC:120%)
Power supply 100-240VAC 50/60Hz
★ 5VDC
(Except for M5W)
★ 24-70VDC
110/220VAC 50/60Hz
★ 24-70VDC
★ 100-240VAC 50/60Hz
Allowable voltage range 90 to 110% of rated voltage
Power consumption DC: 2W, AC: 4VA DC: 3W, AC: 5VA
Display method 7 Segment LED display(Charachter height: 14mm)
Character height M4Y, M4W, M5W : 14mm / M4W1P, M4W2P, M4M1P, M4M2P : 10mm
Display accuracy DC : F.S. ±0.2% rdg ±1 digit AC : F.S. ±0.5% rdg ±1 digit
Sampling period 300ms
A/D conversion method Dual slope Integral method
Response time 2sec.(0 to Max.)
Display frequency 2.5 tlmes/sec.
Contact capacity - Relay conatact output :
250VAC 3A 1c
Relay conatact output :
250VAC 3A 1c×2
Insulation resistance 100MΩ(at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1 minute
Noise strength ±1kV the square wave noise(pulse width : 1㎲) by the noise simulator
Vibration Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) In each of X, Y, Z directions for 10 minutes
Shock Mechanical 300m/s²(30G) in X, Y, Z directions for 3 times
Malfunction 100m/s²(10G) in X, Y, Z directions for 3 times
Relay life cycle Mechanical - Min. 10,000,000 operations
Malfunction - Min. 100,000 operations (250VAC 3A resistive load)
Environ-ment Ambient emperature -10 to 50℃, storage: -20 to 60℃
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Unit weight M4Y:Approx. 144g
M5W:Approx. 172g
M4W:Approx. 168g
M4M:Approx. 262g
(M4M-P:Approx. 268g)
M4W1P:Approx. 253g
M4M1P:Approx. 290g
M4W2P:Approx. 278g
M4M2P:Approx. 316g

※ "★" symbol in power supply is optional. (Customizable)

Cr. : http://www.autonics.com/