Measuring range: 200Pa-10MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: 0.075% URL, optional 0.05% URL Process connection: M20*1.5(M), 1/2-14NPT(F), 1/4-18NPT(F) Measuring medium: Liquid, gas, or steam flow as well as liquid level, density and pressure
|
 |
Measuring range: 2kPa-10MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: 0.15% URL, optional 0.1% URL Process connection: M20*1.5(M), 1/2-14NPT(F), 1/4-18NPT(F) Measuring medium: Liquid, gas, or steam flow as well as liquid level, density and pressure
|

|
Measuring range: 200Pa-40MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: 0.075% URL, optional 0.05% URL Process connection: M20*1.5(M), 1/2-14NPT(F), 1/4-18NPT(F) Measuring medium: Liquid, gas, or steam flow as well as liquid level, density and pressure
|
 |
Measuring range: 1kPa-40MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: ±0.075% URL, optional ±0.05%URL Process connection: M20*1.5(M), G1/2(M), G1/4(M), 1/2-14NPT(M) etc Diaphragm: SS316L, Hastelloy C
|
 |
Measuring range: 10kPa-3.5MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: ±0.2% URL, ±0.5% URL Process connection: M20*1.5(M), G1/2(M), G1/4(M), 1/2-14NPT(M) Measuring medium: Liquid, gas, or steam
|
 |
Measuring range: 5kPa-100MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: 0.2% URL, 0.5% URL, optional 0.1%URL Process connection: M20*1.5 (M), G1/2 (M), G1/4(M), 1/2 -14NPT(M), 1/4 -18NPT(M) etc Measuring medium: Liquid, gas or steam
|
 |
Measuring range: 10kPa-3.5MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: 0.2% URL, 0.5% URL Process connection: M20*1.5 (M), G1/2 (M), G1/4(M), 1/2 -14NPT(M), 1/4 -18NPT(M), etc Measuring medium: Liquid, gas or steam
|
 |
Measuring range: 200Pa - 40MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: ±0.075% URL, optional ±0.05%URL Process connection: M20*1.5(M), G1/2(M), G1/4(M), 1/2-14NPT(M) etc Measuring medium: Liquid, gas, or steam flow as well as liquid level, density and pressure
|
|
Measuring range: 200Pa - 10MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: 0.075% URL, optional 0.05% URL Process connection: M20*1.5(M), G1/2(M), G1/4(M), 1/2-14NPT(M) etc Measuring medium: Liquid, gas, or steam flow as well as liquid level, density and pressure
|
|
Measuring range: 200Pa - 10MPa Output signal: 4-20mA, 4-20mA+HART, customer Reference accuracy: 0.15% URL, optional 0.1% URL Process connection: M20*1.5(M), G1/2(M), G1/4(M), 1/2-14NPT(M) etc Measuring medium: Liquid, gas, or steam flow as well as liquid level, density and pressure
|