BLH NOBEL : KOM-1
Suitable for load and level monitoring in storage tanks
Rugged design
ATEX approved
Simple installation
Applications:
Process weighing
Level monitoring
RANGE kN | A | B | C | D | E | F | G | H ±1 | J | K 0;-1 | ØL | M | N | P | R | S | T | U 0;-1 | V 0;-1 |
5-10-50 | 120 | 100 | 10 | 120 | 100 | 10 | 70 | 89 | 70 | 15 | 11 | M12 | 18 | 33 | 50 | 47 | 10 | 15 | 15 |
100 | 120 | 100 | 10 | 120 | 100 | 10 | 70 | 89 | 70 | 15 | 11 | M12 | 18 | 48 | 50 | 60 | 10 | 20 | 20 |
200 | 140 | 90 | 25 | 170 | 140 | 15 | 100 | 135 | 100 | 24 | 14 | M16 | 28 | 48 | 70 | 50 | 10 | 30 | 20 |
TECHNICAL CHARACTERISTICS KOM-1
Rated load (R.L.): | 10, 20, 50, 100, 200 kN |
Combined error: | 0.25% of R.O. |
Repeatability: | 0.25% of R.O. |
Safe overload: | 100% of R.L.* |
Ultimate overload: | 200% of R.L.* |
Recommended input: | 10 Vdc/ac |
Input voltage maximum: | 18 Vdc/ac |
Input resistance: | 350 ± 5 Ohm |
Output resistance: | 350 ± 5 Ohm |
Rated output (R.O.): | 1 mV/V |
Zero balance: | ±5% of R.O. |
Tolerance of shunt calibration values: | ±1% of value** |
Temperature range: | -40 to +80 (+100)°C*** |
Temp. effect (-10°C to +50°C) on output: | ±0.04% of output/°C |
Temp. effect (-10° to +50°C) on zero balance: | ±0.04% of R.O./°C |
Insulation resistance at 200V DC: | > 4 G Ohm |
Material (load cell): | Stainless steel |
Material (accessories): | Yellow chromate steel**** |
Electrical connection: | 5m shielded four conductor cable 10, 20, 50kN 10m shielded four conductor cable 100, 200kN |
Degree of protection: | IP67 |
* Referring to recommended loading point | |
** See the calibration chart of the load cell | |
*** -40 ÷ +100°C on demand | |
**** Stainless steel on demand | |
ATEX certified versions for use in explosive zones are available |
Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi