BLH NOBEL : KOM-1

Suitable for load and level monitoring in storage tanks 

Rugged design 

ATEX approved 

Simple installation 

 

Applications:

Process weighing 

Level monitoring

RANGE kN A B C D E F G ±1 J 0;-1 ØL M N P R S T 0;-1 0;-1
5-10-50 120 100 10 120 100 10 70 89 70 15 11 M12 18 33 50 47 10 15 15
100 120 100 10 120 100 10 70 89 70 15 11 M12 18 48 50 60 10 20 20
200 140 90 25 170 140 15 100 135 100 24 14 M16 28 48 70 50 10 30 20

TECHNICAL CHARACTERISTICS KOM-1

Rated load (R.L.): 10, 20, 50, 100, 200 kN
Combined error: 0.25% of R.O.
Repeatability: 0.25% of R.O.
Safe overload: 100% of R.L.*
Ultimate overload: 200% of R.L.*
Recommended input: 10 Vdc/ac
Input voltage maximum: 18 Vdc/ac
Input resistance: 350 ± 5 Ohm
Output resistance: 350 ± 5 Ohm
Rated output (R.O.): 1 mV/V
Zero balance: ±5% of R.O.
Tolerance of shunt calibration values: ±1% of value**
Temperature range: -40 to +80 (+100)°C***
Temp. effect (-10°C to +50°C) on output: ±0.04% of output/°C
Temp. effect (-10° to +50°C) on zero balance: ±0.04% of R.O./°C
Insulation resistance at 200V DC: > 4 G Ohm
Material (load cell): Stainless steel
Material (accessories): Yellow chromate steel****
Electrical connection: 5m shielded four conductor cable 10, 20, 50kN 10m shielded four conductor cable 100, 200kN
Degree of protection: IP67
* Referring to recommended loading point  
** See the calibration chart of the load cell  
*** -40 ÷ +100°C on demand  
**** Stainless steel on demand  
ATEX certified versions for use in explosive zones are available  
 
 
 
Accessories are not to be considered included in the price of each product.