BLH NOBEL : KIMD-1
Simple installation
No extra mounting detail is needed
Suitable for weighing in large size
ATEX approved for hazardous areas
Movable load point
TECHNICAL CHARACTERISTICS KIMD-1
Rated load (R.L.): | 500, 800 kN |
Combined error: | ±0.1% of R.O. |
Repeatability: | 0.02% of R.O. |
Safe overload: | 50% of R.L.* |
Ultimate overload: | 100% of R.L.* |
Recommended input: | 10 Vdc/ac |
Input voltage maximum: | 18 Vdc/ac |
Input resistance: | 350 ± 5 Ohm |
Output resistance: | 350 ± 0.5 Ohm |
Rated output (R.O.): | 2.040 mV/V ±0.25% |
Zero balance: | ±2% of R.O. |
Tolerance of shunt calibration values: | ±0.25% of value** |
Creep (30 minutes): | ±0.03% of R.L. |
Temperature range: | -40 / +80 (+100)*** |
Temperature effect (-10°C to +50°C) (14 to 120°F) On output: | ±0.003% of output/°C |
Temperature effect (-10°C to +50°C) (14 to 120°F) On Zero balance: | ±0.003% of R.O./°C |
Insulation resistance at 200 V DC: | > 4 G Ohm |
Material: | Yellow chromate steel |
Electrical connection: | 10 m shielded four conductor cable |
Degree of protection: | IP67 |
ATEX certified versions for use in explosive atmospheres are available. II 1GD EEx ia IIC T4 Tamb = 60°C | |
* With reference to the loading point recommended | |
** See the calibration chart of the load cell | |
*** -40° ÷ +100°C on demand |
Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi