BLH NOBEL : KIS-8
Simple installation
Moveable load point
Withstands very high lateral forces
Extremely accurate and rugged
ATEX certified for hazardous locations
Applications:
Silo/bin/hopper inventory weighing systems
Mixing and blending tanks
Force measurement systems
Conveyors
RANGE kN | A1 | A2 | A3 | A4 | A5 | A6 | A7 | B1 | B2 | B3 | B4 | B5 | C | ØD | E | F | G | H1 |
1-2 | 175 | 151 | 12 | 31 | 31 | 20 | -6 | 75 | 70 | 51 | 55 | 48 | 14 | 33 | 54 | 39 | 78 | 81 |
5-10-20 | 204 | 180 | 12 | 32 | 50 | 20 | 21 | 100 | 100 | 76 | 75 | 73 | 12 | 50 | 56 | 53 | 79 | 107.5 |
50 | 280 | 245 | 17.5 | 46.5 | 65 | 30 | 21 | 150 | 150 | 115 | 115 | 97 | 14 | 75 | 72 | 72 | 97 | 152 |
100 | 310 | 270 | 20 | 63 | 65 | 39 | 22 | 170 | 160 | 130 | 126 | 118 | 15 | 90 | 78 | 88 | 108 | 173 |
200 | 340 | 300 | 20 | 71 | 65 | 49 | 37 | 180 | 190 | 140 | 146 | 132 | 16 | 100 | 92 | 96 | 128 | 199 |
RANGE kN | H2 | H3 | H4 | H5 | H6 | H7 | I | J | ØK | L | ØM | P | C.Clip (2x) | R | S |
1-2 | 14 | 67 | 41 | 48 | 27.5 | 14 | 22 | 30 | 8.5 | M6x80 | 11 | 16 | 32x1.5 | M8 | 19 |
5-10-20 | 18 | 89.5 | 54 | 68 | 38.5 | 18 | 26.5 | 77 | 11 | M10x80 | 12 | 11.5 | 50x2 | M10 | 27 |
50 | 28 | 124 | 72 | 94 | 54.5 | 28 | 36 | 98 | 18 | M12x110 | 15 | 17 | 75x2.5 | M16 | 43 |
100 | 28 | 145 | 85 | 108 | 65 | 38 | 57 | 96 | 22 | M16x140 | 22 | 17 | 90x3 | M20 | 50 |
200 | 36 | 163 | 95 | 118 | 72 | 48 | 80 | 96 | 25 | M20x150 | 25 | 17 | 100x3 | M24 | 57 |
TECHNICAL CHARACTERISTICS KIS-8
Rated load (R.L.): | 1, 2, 5, 10, 20, 50, 100, 200 kN |
Combined error: | ±0.075% of R.O. |
Repeatability: | ±0.02% of R.O. |
Safe overload: | 50% of R.L.* |
Ultimate overload: | 100% of R.L.* |
Ultimate sideload: | 100% of R.L.* |
Recommended input: | 5 Vdc or Vac |
Input voltage maximum: | 18 Vdc or Vac |
Input resistance: | 350 ± 5 Ohms |
Output resistance: | 350 ± 0.5 Ohms |
Rated output (R.O.): | 2.040 mV/V ±0.25% |
Zero balance: | ±2% of R.O. |
Tolerance of shunt calibration values: | ±0.25% of value** |
Creep (30 minutes): | ±0.03% of R.L. |
Temperature range: | - 40 ÷ + 80 (+ 100) °C *** |
Temp. effect (-10°C to +50°C) (14 to 120°F) On output: | ±0.003% of output/°C |
Temp. effect (-10°C to +50°C) (14 to 120°F) On Zero balance: | ±0.003% of R.O./°C |
Insulation resistance at 200V DC: | > 4 G Ohms |
Material (load cell): | Stainless steel |
Electrical connection: | 5 m shielded four conductor cable 1, 2, 5, 10, 20 kN |
10 m shielded cable with four conductors 50, 100, 200 kN | |
Degree of protection: | IP67 |
ATEX certified versions available for use in hazardous areas are available II 1GD | |
* With reference to the loading point recommended | |
** See the calibration chart of the load cell | |
*** On demand -40° ÷ +100°C |
Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi