BLH NOBEL : KIS-8

Simple installation

Moveable load point

Withstands very high lateral forces

Extremely accurate and rugged

ATEX certified for hazardous locations

 

 

Applications:
 
Silo/bin/hopper inventory weighing systems
Mixing and blending tanks
Force measurement systems
Conveyors
 
RANGE kN A1 A2 A3  A4  A5  A6  A7  B1  B2  B3  B4 B5 C ØD E F G H1
1-2  175 151  12 31   31 20  -6  75  70  51  55 48 14 33 54 39 78 81
5-10-20  204 180  12  32  50  20  21  100  100  76  75 73 12 50 56 53 79 107.5
50 280  245  17.5  46.5  65  30  21  150  150  115  115 97 14 75 72 72 97 152
100  310  270  20  63  65  39  22  170  160  130  126 118 15 90 78 88 108 173
200  340  300  20  71  65  49  37  180  190  140  146 132 16 100 92 96 128 199

 

 

RANGE kN H2  H3  H4  H5  H6  H7  ØK  ØM P C.Clip (2x) R S
1-2 14  67  41  48  27.5 14  22  30  8.5  M6x80 11 16 32x1.5 M8 19
5-10-20 18  89.5  54  68  38.5  18  26.5 77  11  M10x80 12 11.5 50x2 M10 27
50  28  124  72  94  54.5  28  36  98  18  M12x110 15 17 75x2.5 M16 43
100  28  145  85  108  65  38  57  96  22  M16x140  22 17 90x3 M20 50
200  36  163  95  118  72  48  80  96  25  M20x150  25 17 100x3 M24 57

 

 

 

 

 

 

 

 

TECHNICAL CHARACTERISTICS KIS-8

Rated load (R.L.): 1, 2, 5, 10, 20, 50, 100, 200 kN
Combined error: ±0.075% of R.O.
Repeatability: ±0.02% of R.O.
Safe overload: 50% of R.L.*
Ultimate overload: 100% of R.L.*
Ultimate sideload: 100% of R.L.*
Recommended input: 5 Vdc or Vac
Input voltage maximum: 18 Vdc or Vac
Input resistance: 350 ± 5 Ohms
Output resistance: 350 ± 0.5 Ohms
Rated output (R.O.): 2.040 mV/V ±0.25%
Zero balance: ±2% of R.O.
Tolerance of shunt calibration values: ±0.25% of value**
Creep (30 minutes): ±0.03% of R.L.
Temperature range: - 40 ÷ + 80 (+ 100) °C ***
Temp. effect (-10°C to +50°C) (14 to 120°F) On output: ±0.003% of output/°C
Temp. effect (-10°C to +50°C) (14 to 120°F) On Zero balance: ±0.003% of R.O./°C
Insulation resistance at 200V DC: > 4 G Ohms
Material (load cell): Stainless steel
Electrical connection: 5 m shielded four conductor cable 1, 2, 5, 10, 20 kN
  10 m shielded cable with four conductors 50, 100, 200 kN
Degree of protection: IP67
ATEX certified versions available for use in hazardous areas are available II 1GD  
* With reference to the loading point recommended  
** See the calibration chart of the load cell  
*** On demand -40° ÷ +100°C  
 
 
 
Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi

Video