C2G1 HT
High temperature version
Particularly suitable for the construction of industrial and electronic weighing scales, counter scales, counting and packaging machines
Insensitive to off-center weights
3000 and 6000 divisions O.I.M.L. R60 C Class approved
High precision, high reliability and long life
IP64 protection
Plateform maximum size 300x300 mm
Electrical Connection | |
+Excitation | Red |
-Excitation | Black |
+Signal | Green |
-Signal | White |
+Sense | Blue |
-Sense | Brown |
TECHNICAL CHARACTERISTICS C2G1 HT
Rated load (RL): | 6 - 10 - 12 - 15 - 20 - 25 - 30 - 35 - 50 - 60 - 100 Kg |
Non-Linearity: | ±0,015 % of R.O. |
Repeatability: | ±0,02 % of R.O. |
Creep (20 minutes): | ±0,02 % of R.L. |
Safe overload: | 150 % of RL |
Maximum overload: | 200 % of R.L. |
Recommended input: | 5 ÷ 12 Vdc/Vac |
Input resistance: | 420 +30/-20 Ohm |
Output resistance: | 350 ±5 Ohms |
Insulation resistance: | > 2000 M Ohms |
Rated output (R.O.): | 2 ±0.2 mV/V |
Zero balance: | < ±0.1 mV/V |
Temperature range: | -10 ÷ +150 °C |
Compensated temperature range: | -10 ÷ +120 °C |
Temperature effect on zero balance: | ±0.004 % of R.O./°C |
Temperature effect on output: | ±0.0012 % of output/°C |
Max load deflection: | 0.17 ÷ 0.62 mm |
Precision class: | 3000 n. OIML - 6000 n. OIML |
Degree of protection: | IP64 |
Material: | Stainless steel |
Electrical connection: | 4 conductors shielded cable; length 2 m |
Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi