Temperature Controllers : NC200 & DL200

 

DESCRIPTION  : 

The NC200 is a compact fuzzy logic plus PID temperature controller with J or K type thermocouple or RTD input. Multiple units (up to 247 units) can be networked together with 4P4C modular connector. Each unit auto-tunes on initial setup to provide the best response for each heater. The NC200 is powered by 90-250VAC supply and contains a solid state relay as its control output. The solid state relay can drive the heater directly through a plug-in connector. The major features of the unit are as following:
* COMPACT SIZE
* EASY INSTALLATION
* SELF ADDRESSING
* FAST COMMUNICATION SPEED

 

DL200 is a data logger which can connect up to 247 Network Temperature Controllers Model NC200. This unit can write all commands and read all data to and from each Network Temperature Controllers Model NC200 after equipping the unit with a HMI or PC via RS-232 port. The unit provides a dry contact which will be closed when one or more of the Network Temperature Controllers Model NC200 are outside of high and low limits or hardware failure occurs.

 

As a professional and experienced manufacturer, we supply high-performance and quality temperature controllers, which are also called temperature control, electronic temperature control, and electronic temperature controller.

 

FEATURES 

  • Auto addressing, manual setting unnecessary
  • Network up to 247 controllers
  • The fastest speed, taking 1 second to update 1000 data
  • Used with SCADA, HMI via Modbus RTU
  • Quick connector for easy and safe wirings

 

NC200 

 

Power
90 ~ 250 VAC, 47 ~ 63 Hz, 800VA maximum

 

INPUT:

Type
Range
Accuracy
Input Impedance
J

-17.8°C ~ 500 °C
( 0°F ~ 932 °F )

±2 °C
1MΩ
K
-17.8°C ~ 500 °C
( 0°F ~ 932 °F )
±2 °C
1MΩ
PT100
(DIN)
-17.8°C ~ 500 °C
( 0°F ~ 932 °F )
±1 °C
1.3KΩ

 

Output (Solid state relay)

 

 

Relay Rating : 7A @25 C, 3.5A @47.5 C ambient temperature,
                       90 ~ 250 VAC, 47 ~ 63Hz.
                       See Fig.16 Load derating curve
Switch ON-OFF: Zero crossing triggering
Insulation resistance: 1000 Mohms min. at 500 VDC
Dielectric strength: 2500 VAC for 1 minute.

Data Communication
Interface : RS-232 ( 1 unit ), RS-485 ( up to 247 units )
Protocol : Modbus Protocol RTU mode
Address : 1 - 247
Baud Rate : 2.4 ~ 38.4 Kbits/sec
Parity Bit : None, Even or Odd
Stop Bit : 1 or 2 bits
Communication Buffer : 64 bytes
 
Control Mode
Action Reverse (heating)
PID mode:
       PB= 1-500 °C 
       TI= 1-900 sec. 
       TD= 0-300 sec.
Cycle time: 2 seconds
Manual control: 0-100%
Auto-tuning: Cold start and warm start
Power limit: 0-100%
 
Environmental & Physical
Operating Temperature : -10°C to 50°C
Storage Temperature : -40°C to 60°C
Humidity : 0 ~ 90 % RH ( non-condensing )
Altitude : 2000m maximum
Insulation Resistance : 20 Mohms min. ( at 500 VDC )
Dielectric Strength : 1350 VAC, 50/60 Hz for 1 minute
Vibration Resistance : 10 - 55 Hz, 10 m/s² for 2 hours
Shock Resistance : 200 m/s² ( 20 g )
Dimensions :
NC200 --- 50.3(W) x 52.4(L) x 45(H) mmWeight --- 112 grams
 
Approval Standards
Safety : EN61010-1
 
Protective Class : IP 20
 
EMC : EN61326
 
DL200 
Power
90~250 VAC, 47~63 Hz, 3VA, 1W maximumAlarm
 
Alarm
Relay: Form A, Rating 2A/240VAC, life cycles 200,000 for resistive load.
Alarm Function: low alarm or high alarm or hardware failure or sensor break occurs for any unit on line.
Alarm Indicator: Red colorInterface
Master Side: RS-232
Slave Side: RS-422Data Communication
Master Side: 
Protocol: Modbus Protocol RTU Mode
Address: 20 (fixed)
Baud Rate: 38.4 Kbits/sec
Data Bit: 8 bits
Parity Bit: Even
Stop Bit: 1 bit
Reading Speed: 60ms for reading one word of data for 100
                          units, 480ms for reading 4 words of data for 200 units.Master Side: 
Interface: Differential driver/receiver
Protocol: Proprietary protocol
Baud Rate: 92.16 Kbits/sec
Reading Speed: 4ms/unit (reading 14 words per unit )
Writing Speed: 3.5 ms for writing 10 words
                         1.5 ms for writing 1 word.Environmental & Physical
Operating Temperature : -10°C to 50°C
Storage Temperature : -40°C to 60°C
Humidity : 0 ~ 90 % RH ( non-condensing )
Altitude : 2000m maximum
Insulation Resistance : 20 Mohms min. ( at 500 VDC )
Dielectric Strength : 2300 VAC, 50/60 Hz for 1 minute
Vibration Resistance : 10 - 55 Hz, 10 m/s² for 2 hours
Shock Resistance : 200 m/s² ( 20 g )
Dimensions : 102.5 (L) X 80 (W) X 30 (H) mm
Weight --- 120 grams
Approval Standards
Safety : EN61010-1Protective Class : IP 20EMC : EN61326

 

ORDERING CODE  : 

NC200 -
  1 2 3 4

 

 

1 Power Input
4: 90 ~ 250 VAC, 47-63 HZ

 

2 Signal Input
1: Standard Input
Thermocouple: J, K
RTD: PT100 DIN
9: Special Order

 

3 Control Output
3: Solid State Relay, 3A/250VAC

 

4 Options
0: °C
1: °F

 

Standard ordering code = NC200-4130

 

 

 

 

DL200 -
  1 2 3 4

 

1 Power Input
4: 90 ~ 250 VAC, 47-63 HZ

 

2 Alarm Output
1: Form A Relay,2A/250VAC

 

3 Communication
1: RS-232, Modbus protocol
2: Special order

 

4 Options
0: No special option

 

Standard ordering code = DL200-4110

 

DOCUMENTATION  : 

User Manual: UMNC200B ( 87.8KB / 2pages )
                     UMDL200B ( 151KB / 2pages )

 

 

Cr : http://www.brainchild.com.tw/