Low-cost hybrid recorder
CR06 6 - channel dotting chart recorder
DESCRIPTION :
It is dotting style of 6 - channel chart recorder, universal input, low cost, short depth 150mm, light weight 1.5 kgs and IP65 water-resistance.
As a professional and experienced manufacturer, we supply high-performance and quality paperless recorders, video graphic recorders, paperless chart recorders, chart recorders, and temperature chart recorders.
FEATURES
6-channel dotting
Short depth in 150mm
Weights 1.5kg only
Dust-proof.IP-65 Water-resistance
Standard RS-232 Communication interface
Universal input and range
UL, CSA, CE approved
144Wx144Hx150D mm
SPECIFICATIONS :
INPUT
Nos. of input: 6
Input sampling: 10s/6ch, max
Type of input: Direct voltage: ±10mV, 0-20mV, 0-50mV, ±1V, 1-5V
Direct ourrent: 4-20mA
Thermocouple: K, T, J, E,B,S,R,G,C,N,PR40-20, PLII, L, Au-Fe
RTD: Pt100, Pt50, JPt100
PERFORMANCE
Accuracy: ±0.2%±1 digit max. for Digital indicator/printing
Noise reduction : NMRR: 60dB min.
CMRR: 140dB min.
Isolation resistance: Each terminals/ground: 500VDC, 20MΩ min.
Dielectric strength: Power input terminal/ground: 1.5kVAC, 1 minute
Input terminal/ground: 0.5kVAC, 1 minute
ALARM
Nos. of relay outputs: 6 outs (Form a contacts; Built-in option)
Capacity: 30VDC 3A Max. Loaded
COMMUNICATION
Interface: RS-232C (Standard), RS-485 (Modbus RTU: Option)
POWER SUPPLY
Rated power voltage: 100-240VAC (50/60Hz)
Power consumption: 25VA max.
STRUCTURE
Mounting/housing: Panel mounting/Front panel: Dust-proof,
Water-proof (IP-65)
Dimension: 144(W) x 144(H) x 150(D) mm
Weight: 1.5kg max.
OPERATION CONDITION
allowable conditions: Temperature: 0-50°C, Humidity: 20-80%
RECORDING / PRINTING PERFORMANCE
Recording: Raster-scan printing
Printing: Dotting with 6 color ribbon
Dot print interval: 10.0s/6ch max.
Chart paper: Length: 16m, Dotting width: 100mm
Chart speed: User-selective from 28 speed
In range: 10-1500mm/hr
Printing color: Purple, Red, Green, Blue, Brown, Black
ORDERING CODE :
CR06 - | □ | □ | □ |
1 | 2 | 3 |
1 COMMUNICATION
0: standard RS - 232
1: RS - 485
2 DI/DO (digital input/output)
0: none
1: 6 relay output
2: 3 DI
3: 3 DI + 6 relay output
3 OUT-OF-PAPER SENSOR
0: none
1: yes
DOCUMENTATION :
Brochure: LFCR06 ( 253KB / 2 pages )
User Manual: UMCR061B (2.61 MB / 114 pages )