Loadcell Transmitter : PD-20 S

 

Information

Puls Transmitter PD-20 S is designed to combine reliable weight information from process vessels with extremely easy operation and setup. A wide range of strain gauge load cells can be connected and output is provided in the common 4... 20 mA signal format. With its DIN-rail mount, it is easy to place. It is an economic aplifier for control and weighing applications in the industry."

 

Tachnical specification

GENERAL

Power Supply

18 - 36 VDC

Inputs

1 Unit Digital
1 Unit Analog (Load Cell)

Outputs

16 Bit Analog Output (0-10V, 4-20mA , 0-20mA)
Modbus (RS485)
Transistor Output (500 mA)

Protection Class

IP 54

DISPLAY

Display

7 mm 7 Segment DISPLAY

Display Step

x1 , x2 , x5, x10, x20, x50

Decimal Display

0.1, 0.01, 0.001

Keypad

4 Units Membrane Type

A / D CONVERTER

Type

24 bit Delta-Sigma ADC

Converting Speed

100 HZ

Display Precision

1/100.000

FILTER AND CALIBRATION

Digital Signal Filter

It is internal filter of ADC.

Anti-vibration Filter

Special Filter for Vibrated Environments

Parametric Calibration

Done while being connected to the Load Cell

Weighted Calibration

With standard weights.

LOAD CELL

Power Supply

10 V DC

Number of Load Cells

4 Units 350 Ω

Output Signal at Max Load

≤ 4 mV/V

Connection

Connection with 4 or 6-core cable.

COMM. INTERFACE

Serial Port - Modbus

RS 485

Serial Port - Free Protocol

RS 232

AMBIENT AND EQUIPMENT

Operating Temperature

-10 °C ~ +40 °C

Humidity

%85

Box

RAIL MOUNT SPECIAL PLASTIC TYPE

 

PD-20 S Loadcell Transmitter Technical Drawing

PD-20 S Loadcell Transmitter Catalog

 

 

 

Cr : http://www.pulselectronic.com/