Load Cell : BT Series

 

Information

The BT series load cell was developed for low or middle capacity applications. It has special alloy steel and shows high results in weighing performance.
This stainless steel and nickel-plated load cell is highly protected from external agents such as rain, dust, water that can make troubles for a good performance.
The BT load cell works with principle of bending beam. Due to that some vibrations appearing during the weighing process are muffled. That guarantees extremely accurate weighing result.
The cable output of the BT load cell is sealed to metal nipple. The protection level is IP67. The BT load cell is produced with 3 metres lengthwise screened cable.

General Application
- Packaging and filling machines
- Dosing system
- Band weighing machines
- Check weigher
- Tension control applications
- Platform scales with low capacity

Capacity
The BT load cell is produced in 10, 20, 50, 100, 200, 500 kg capacities

 

Tachnical specification

Type

BT

Accuracy class

C1

C3

Capacity (Emax)

10,20,50,100,200,500 kg

Minimum dead load

0% R.O

Rated output R.O

2,0 mV/V

Maximum number of load cell interval Nmax

1000

3000

Vmin

Emax/4000

Emax/10000

Emax / Vmin

4000

10000

Minimum dead load output return (MDLOR)

<0,0500 %R.O

<0,0167 %R.O

Zero balance

1 %R.O

Temperature effect on zero

<< 0,0070 %R.O/5°C

Temperature effect on output

< 0,0055 %R.O/5°C

Compensated temperature range

-10 /+40 °C

Temperature range safe

-30 /+70 °C

Maximum safe central overload

150 %R.O

Ultimate central overload

300 %R.O

Excitation

5 V

Input impedance

380±20 Ω

Output impedance

350±3 Ω

Insulation resistance

>1000 MΩ

Construction

Nickel plated alloy steel

Environmental protection

IP67

Cable type

2x2x0,22 mm

Cable length

3 m

Weight

0,6kg

 

Technical Drawing

BT Series Load Cell Catalog

 

 

 

Cr : http://www.pulselectronic.com/