Load Cell : LT-5C Series
Information
LT-5C series load cells are single ended and made from special alloy steel that isolates it from corrosion and industrial environments. Work with shear beam principle and is nickel plated. LT-5C type load cells were designed for compression applications. It has IP67 nipple cable and stainless steel cover that enhances environmental protection. Ex-proof version is available.
General Applications
- Weighing platfroms
- Bunker weighings
- Silo and tank weighings with low and middle capacities
- Dosing system
- Packaging and filling machines
- Band weighings
Capacity
LT-5C series load cells are produced in 300,500 kg 1,2,3,5 ton capacities
Tachnical specification
Type |
LT-5C |
||
Accuracy class |
C1 |
C3 (OIML R60 ONAYLI) |
|
Capacity (Emax) |
0,3-0,5-1-2-5 T |
||
Minimum dead load |
0% R.O |
||
Rated output R.O |
2,0 mV/V |
||
Maximum number of load cell interval Nmax |
1000 |
3000 |
|
Vmin |
Emax/4000 |
Emax/10000 |
|
Emax / Vmin |
4000 |
10000 |
|
Minimum dead load output return (MDLOR) |
<0,0500 %R.O |
<0,0167 %R.O |
|
Zero balance |
1 %R.O |
||
Temperature effect on zero |
<< 0,0070 %R.O/5°C |
||
Temperature effect on output |
< 0,0055 %R.O/5°C |
||
Compensated temperature range |
-10 /+40 °C |
||
Temperature range safe |
-30 /+70 °C |
||
Maximum safe central overload |
150 %R.O |
||
Ultimate central overload |
300 %R.O |
||
Excitation |
5 V |
||
Input impedance |
380±20 Ω |
||
Output impedance |
350±3 Ω |
||
Insulation resistance |
>1000 MΩ |
||
Construction |
Nickel plated alloy steel |
||
Environmental protection |
IP67 |
||
Cable type |
2X2x0,22 mm |
||
Cable length |
3 m |
||
Weight |
300-500-1000-2000kg: 1,0kg |