Level Transmitters : LD35
DeltaSpan™ IS Submersible Pressure Level Transmitter
Application
The intrinsically safe submersible pressure level transmitter provides continuous level measurement up to 46' (14m) of water column with a 4-20 mA signal output. Select the LD31 liquid level sensor for relatively clean water, light weight oil or diluted chemical. Application examples include wet wells and water remediation.
Features
Corrosion resistant 316 SS body with polyurethane or ETFE cable
Strong cable design with maintenance free breather tube and vent filter
Automatic temperature compensation for accurate measurement
Literature
Specifications
Range: | -SX01: 0 to 5 psi (0.34 bar), 0 to 11' (0 to 3.4m) wc -SX11: 0 to 10 psi (0.69 bar), 0 to 23' (0 to 7m) wc -SX21: 0 to 15 psi (1.0 bar), 0 to 34' (0 to 10.4m) wc -SX31: 0 to 20 psi (1.38 bar), 0 to 46'(0 to 14m) |
Accuracy: | ± 0.25% of full scale |
Configuration: | None, fixed span |
Supply voltage: | 10 to 28 VDC |
Loop resist.: | 900 Ohms @ 28 VDC |
Signal output: | 4-20 mA, two-wire |
Process temp.: | F: 0° to 176° C: -18° to 80° |
Temp. comp.: | F: 0° to 176° C: -18° to 80° |
Proof pressure: | 2 x full scale |
Weight: | 2.2 lb (1.0 kg) |
Trans. rating: | NEMA 6 (IP67) |
Trans. material: | 316 SS, 316L SS, Buna-N & PVC |
Trans. thread: | 1/2" NPT |
Cable type: | 2-conductor, shielded with vent tube |
Cable length: | -SX01 & SX11: 40' (12.2m) -SX21 & SX31: 60' (18.3m) |
Cable material: | -S3X1: Polyurethane (IS) -S4X1: ETFE (IS) |
Classification: | Intrinsically safe Class I Div. 1 Groups A, B, C & D; Class II Div. 1 Groups E, F & G; Class III Div. 1T4 @ 80 °C ambient |
Compliance: | CE, UL Intrinsically safe to UL standard 913 IEC 61000-4-2:2001 IEC 61000-4-3:2006 IEC 61000-4-4:2004 IEC 61000-4-5:2005 IEC 61000-4-6:2006 IEC 61000-4-8:2001 CENELEC EN 55011:2003 CENELEC EN 61326:2003 89/336/EEC EMC Directive |
Parameters: | Vmax = 28 VDC Imax = 93 mA Ci = 0.051_F Li = 240_H Pi = 0.651_W |
Cr : http://flowline.com