Counters/Flow : SPP-N118

SPP-N118 are the flow meters in tight, wall mounted case (IP 65), designed to work in tandem with the pulse flow transducers with current input of 0-20 mA or 4-20 mA. Wide range of total flow (up to 16 significant digits) enables flow volume control for a long time. Build in a batcher function makes possible application of SPP-N118 in a wide range of industry branches (food production, pharmacy, paint and varnish).

 

Parameters

Input measurement: current 0-20 mA or 4-20 mA, overload-protected,sinking current limited to about 40 mA; programmable: binary 24V DC, not separated
Display LED, red (green on request), 6 x 13 mm high, with 8-step adjustment of brighness
Data memory non-volatile memory, EEPROM type
Displayed values range 0 ÷ 999999 + decimal point
Power consumption for 230V AC and 110V AC: max. 2,6 VA; for 24V DC: max. 4,5 W
Output 0 or 2 relay 1A/250V AC (cos fi=1) or OC 30mA/30VDC/100mW; power supply output: 24V DC + 5% -10% / max 100 mA
Communication interface RS-485 / Modbus RTU (not galvanically isolated)
Transmission parameters 1200 ÷ 115200 bit/s, 8N1 and 8N2
Protection class IP 65
Operating temperature 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option)
Accuracy current measurement: 0.1% @25°C (for 0÷20 mA range)
Power supply 230 V AC ± 10%; 110 V AC ± 10%; 24 V DC (non separated from measurement input)
Case wall-mounted
Storage temperature -10°C ÷ +70°C; -20°C do +70°C (depending on version)
Case dimensions without glands: 110 x 80 x 67 mm; with glands: 110 x 105 x 67 mm
Total flow unit I or m3
Instantaneous flow unit l or m3 per second, minute or hour
Total flow precision selected from range: 0 ÷ 0.000
Total flow capacity over 4 x 10^9 m3 with max. resistance 0,001 l
Instantaneous flow precision selected from range: 0 ÷ 0.00000

 

 

Cr : http://www.simex.pl/en