Counters/Electronic : SLE-73

The SLE-73 meters have been designed exclusively for applications where a progressive counting of impulses is required. They feature two entry ports: counting and with a programmable function that can be used for resetting the meter to zero or stopping / changing its direction of travel (as required).

 

Parameters

Inputs pulse; 1 x counting (down-up and up-down) PNP; 1 x programmable (PNP)
Counting mode adding or subtracting
Display LED, red, 6 x 9 mm high
Input levels low: 0 V ÷ 1 V; high: 10 V ÷ 30 V
Input frequency electronic: 3 kHz; contact: max. 90 Hz (adjustable filter)
Data memory non-volatile memory, EEPROM type
Displayed values range -99999 ÷ 999999, with signalling of overfilling
Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
Output power supply output: 24V DC +5%, -10% / max. 100 mA
Communication interface RS-485, 1200 ÷ 115200 bit/s, 8N1 and 8N2, Modbus RTU
Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips)
Reset reset: button and electric, with keyloc
Case material NORYL-GFN2S E1
Operating temperature 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option)
Storage temperature -10°C ÷ +70°C or -20°C ÷ +70°C (with option 08)
Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
Case panel mounting
Panel cut-out dimensions 66,5 x 32,5 mm
Case dimensions 72 x 36 x 97 mm
Installation depth min 102 mm
Typical applications Counting amount of manufactured elements

 

 

Cr : http://www.simex.pl/en