Temperature meter in tight, wall mounting case (IP 65 or IP 67), with a large, readable display, with inputs Pt100, Pt500, Pt1000 or thermocouple, with 1 relay / OC output. The version without relay outputs is also available.

 

Parameters

Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
Input thermoresistance: Pt100, Pt500, Pt1000; thermocouple: type K, S, J, T, N, R, B, E
Display LED, red, 4 x 57 mm, with 8-step adjustment of brighness
Measurement range -100°C ÷ 600°C for Pt100, Pt500, Pt1000; thermocouples K: -200°C ÷ +1370°C; S: -50°C ÷ +1768°C; J: -210°C ÷ +1200°C; T: -200°C ÷ +400°C; N: -200°C ÷ +1300°C; R: -50°C ÷ +1768°C; B: +250°C ÷ +1820°C; E: -200°C ÷ +1000°C; additional range -10 ÷ +90 mV
Stability typ. 50 ppm/°C
Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 11 VA; 19V ÷ 50V DC power supply: max. 8 W
Output 0 or 1 relay 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
Resolution 0,1°C for Pt100, Pt500, Pt1000; 1°C for thermocouples
Communication interface RS-485, 8N1 and 8N2, 1200 ÷ 115200 bit/s, Modbus RTU
Protection class IP 65 (standard); IP 67 (option)
Case material ABS + glass fibre
Operating temperature 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option)
Case wall-mounted (depends on IP version)
Storage temperature -10°C ÷ +70°C or -20°C ÷ +70°C (with option 08)
Accuracy 0,1% @25°C
Case dimensions IP 65 type case: 215 x 185 x 118,2 mm; IP 67 type case: 230 x 140 x 96,5 mm

 

 

Cr : http://www.simex.pl/en