Temperature meter with a large, readable display, with inputs Pt100, Pt500, Pt1000 or thermocouple, with 2 or 4 relay / OC outputs. The version without relay outputs is also available.

 

Parameters

Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
Input thermoresistance: Pt100, Pt500, Pt1000; thermocouple: type K, S, J, T, N, R, B, E
Display LED, 4 x 20 mm high, red (green on request)
Measurement range -100°C ÷ 600°C for Pt100, Pt500, Pt1000; thermocouples K: -200°C ÷ +1370°C; S: -50°C ÷ +1768°C; J: -210°C ÷ +1200°C; T: -200°C ÷ +400°C; N: -200°C ÷ +1300°C; R: -50°C ÷ +1768°C; B: +250°C ÷ +1820°C; E: -200°C ÷ +1000°C; additional range -10 ÷ +90 mV
Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
Stability typ. 50 ppm/°C
Resolution 0,1°C for Pt100, Pt500, Pt1000; 1°C for thermocouples
Output 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs; active current output: operating range max. 0 - 24 mA, load resistance max. 700 Ohm
Communication interface RS-485, 8N1 and 8N2, 1200 ÷ 115200 bit/s, Modbus RTU
Case material NORYL - GFN2S E1
Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips)
Operating temperature 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option)
Case panel mounting
Accuracy 0,1% @25°C
Storage temperature -10°C ÷ +70°C or -20°C ÷ +70°C (with option 08)
Case dimensions 96 x 48 x 100 mm
Panel cut-out dimensions 90,5 x 43 mm
Installation depth min. 102 mm

 

 

Cr : http://www.simex.pl/en