Indicator : DN520N
- Application of Packer, Filler, Hopper, Checker, Limit Scale, etc.
- Totaling function by Parts.(50 parts)
- 2 Step Control (SP1, SP2)
- 6 Control RELAY according to MODE
- LIMIT, PACKER MODE: (SP1, SP2, FINISH, UNDER NG, OVER NG, ZERO)
- CHECKER MODE 1, 2, 3 : (SP1[LOW], SP2[HIGH], OK, NG, ZERO)
- RELAY OUTPUT MODE: LIMIT, PACKER, CHECKER
- Improved A/D Conversion speed and resolution(Max. 200times, 1/520,000)
SPECIFICATIONS
Specifications | Accuracy |
---|---|
Load cell excitation | 10VDC±5%, 320mA |
Input Signal | 0.5 ~ 3.0mV/V |
A/D converting speed | 200times/sec |
A/D converter resolution | 1/520,000 counts(19bits), Δ∑ |
Non-linearity | 0.01% of full scale |
Zero adjustment range | -0.6mV~42mV |
Display Unit | 7 segment, 20.0mm(H)×13.0(W)mm |
Annunciator | steady, zero, tare, gross, auto, print, hold,Interface |
Decimal point position | 0, 0.0, 0.00, 0.000 |
Keyboard | Number key and function key 12 PCS. |
Temperature-drift | zero ±20PPM/℃, span ±20PPM/℃ |
Non-linearity | 0.01% of full scale |
Rear panel | Loadcell input : 5pin connector External control : 12pin input terminal (zero, tare, tare reset/hold/print, gross/hold reset/subprint, Current loop,RS232C) control relay output : 7pin terminal |
Power | SMPS Free Voltage (85V~265V) |
Option
- Analog Out-put (V-out) : 0~10V
- Analog Out-put (I-out) : 4~20mA
- Serial I / F : RS-422, RS-485
- BCD In-put
- BCD In-out
- RS3232C and Current loop : Standard Installed
DIMENSIONS