Load cell : CS131
- CS131 uses Crane and Overload applications
- Electroless nickel plated for corrosion resistance.
SPECIFICATIONS
Specifications | Accuracy |
---|---|
Rated capacity (R.O) | 8tf, 10tf, 25tf |
Rated output (R.O) | 2mv/v±0.3% |
Non-linearity | 0.5% R.O. |
Hysteresis | 0.5% R.O. |
Repeatability | 0.5% R.O. |
Zero balance | 1±1% R.O. |
Temp. Range Compensated | -10~40℃ |
Temp. Effect on Rated Output | ±0.05% Load/10℃ |
Temp. Effect on Zero Balance | ±0.05% R.O./10℃ |
Resistance, Input | 700Ω±3.5Ω |
Resistnace, output | 700Ω±5Ω |
Insulation Resistance Bridge To Ground | 2000㏁ |
Electrical Connection | φ7mm×4C×10m |
Exc. Recommended | 10V |
Safe Overload | 150% R.C. |