SPECIFICATIONS
| Specifications | Accuracy |
| Rated Capacity(R.O.) |
500gf, 2kgf |
| Safe Overload |
150% R.C |
| Ultimate overload |
150% R.C |
| Rated Output |
1.0mV/V |
| Nonlinearity |
0.2% of R.O. |
| Hysteresis |
0.2% of R.O. |
| Repeatability |
0.2% R.O. |
| Excitation recommended |
5V |
| Zer Balance |
±0.2mV/V |
| Input resistance |
350Ω±40Ω |
| Output resistance |
350Ω±40Ω |
| Insulation resistance |
1000㏁ or more (DC 50V) |
| Temperature range, compensated |
0℃~50℃ |
| Temperature range, safe |
-10℃~60℃ |
| Temperature effect on zero balance |
0.5% R.O. / 10℃ |
| Temperature effect on output |
0.5% load / 10℃ |
| Cable |
Φ3 4core shield cable, 2m |
Cr : http://www.dacell.com